Enphase X-IQ-AM1-240-3 M, AC Combiner Box with Enphase IQ Envoy
The Enphase IQ Combiner 3™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a pre-wired solution for residential applications.
- 20% reduced size from previous IQ Combiner
- Pre-installed with the IQ Envoy
- PV and storage-ready with combined input of up to 80 A
- Accommodates up to 4-2P Eaton breakers
- Supports single-stud mounting as well as side, bottom, and rear conduit entry
- NEMA 3R outdoor rated enclosure
- UL 1741 listed assembly
- 5-year equipment warranty
Smart - Includes IQ Envoy for communication and control
- Flexible networking supports Wi-Fi, Ethernet, or cellular
- Optional AC receptacle available for PLC bridge
- Provides production metering and optional consumption monitoring
Simple - Reduced size from previous combiner
- Centered mounting brackets support single stud mounting
- Supports back and side conduit entry
- Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included)
- 80 A total PV or storage branch circuits
Reliable
- Durable NRTL-certified NEMA type 3R enclosure
- Five-year warranty
- UL listed
ELECTRICAL SPECIFICATIONSRating |  Continuous duty | System voltage | 120/240 VAC, 60 Hz | Eaton BR series busbar rating | 125 A | Max. continuous current rating (output to grid) | 65 A | Max. fuse/circuit rating (output) | 90 A | Branch circuits (solar and/or storage) | Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) | Max. continuous current rating (input from PV) | 64 A | Max. total branch circuit breaker rating (input) | 80A of distributed generation / 90A with IQ Envoy breaker included | Production Metering CT | 200 A solid core pre-installed and wired to IQ Envoy |
MECHANICAL DATADimensions (WxHxD) | 49.5 x 37.5 x 16.8 cm (19.5” x 14.75” x 6.63”). Height is 21.06" (53.5 cm with mounting brackets). | Weight | 7.5 kg (16.5 lbs) | Ambient temperature range | -40° C to +46° C (-40° to 115° F) | Cooling | Natural convection, plus heat shield | Enclosure environmental rating | Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction | Wire sizes | • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. | Altitude | To 2000 meters (6,560 feet) |
INTERNET CONNECTION OPTIONSIntegrated Wi-Fi | 802.11b/g/n | Ethernet | Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) | Cellular | Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) |
COMPLIANCECompliance, Combiner | UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) | Compliance, IQ Envoy | UL 60601-1/CANCSA 22.2 No. 61010-1 |
ELECTRICAL SPECIFICATIONSRating |  Continuous duty | System voltage | 120/240 VAC, 60 Hz | Eaton BR series busbar rating | 125 A | Max. continuous current rating (output to grid) | 65 A | Max. fuse/circuit rating (output) | 90 A | Branch circuits (solar and/or storage) | Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) | Max. continuous current rating (input from PV) | 64 A | Max. total branch circuit breaker rating (input) | 80A of distributed generation / 90A with IQ Envoy breaker included | Production Metering CT | 200 A solid core pre-installed and wired to IQ Envoy |
MECHANICAL DATADimensions (WxHxD) | 49.5 x 37.5 x 16.8 cm (19.5” x 14.75” x 6.63”). Height is 21.06" (53.5 cm with mounting brackets). | Weight | 7.5 kg (16.5 lbs) | Ambient temperature range | -40° C to +46° C (-40° to 115° F) | Cooling | Natural convection, plus heat shield | Enclosure environmental rating | Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction | Wire sizes | • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. | Altitude | To 2000 meters (6,560 feet) |
INTERNET CONNECTION OPTIONSIntegrated Wi-Fi | 802.11b/g/n | Ethernet | Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) | Cellular | Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) |
COMPLIANCECompliance, Combiner | UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) | Compliance, IQ Envoy | UL 60601-1/CANCSA 22.2 No. 61010-1 |
|
|
|
|
|
|
|