Skip to content
To take full advantage of this site, please enable your browser's JavaScript feature.
Learn how
About Us
My Account
My Cart
www.ForeverPurePlace.com
Menu
Home Water Purification / Conditioning Systems
Filters and RO - Residential
Water Softeners - Residential
Salt-less Scale Prevention Systems
Accessories
Commercial Systems
Commercial RO Systems
Commercial Water Softeners
Filtration Systems w/ Control Valve
Seawater Desalination Systems
Parts / Consumables
Control Valves
Autotrol Valves
Autotrol Accessories
Fleck Valves
Fleck Residential Valves
Fleck Commercial/Ind. Valves
Fleck Accessories
Fleck Replacement Parts
Filter Housings
Filtration Cartridge System
Membrane Housings
Codeline Membrane Vessels
Piedmont Grooved Pipe Couplings
Replacement Filters / Cartridges
Aries
Hydronix Filters
Resin and Filter Media
Softener or Filter Tanks
UV Systems
Water Treatment Chemicals
Chemicals
Membrane / softener Chemicals
Membranes - RO/UF/NF
CSM
LG NanoH2O
Filmtec
Axeon Membranes
Hydranautics
Toray
Water Pumps
Aquatec
CAT Pumps
CAT Pump - Pump Ends and Mounts
CAT Pump Accessories
CAT Pump Parts and Kits
Pumps
Danfoss Pumps
Danfoss Updated 2016
Danfoss 2019
Danfoss APP Pumps
Danfoss PAH Pumps
Danfoss Pump Accessories
Energy Recovery Inc. (ERI)
PX Units
FEDCO
Procon Pump
Wilo Pumps
Wilo Helix Pumps (vertical)
Wilo Pump -- 3HS
Wilo Pump -- BLZ
Wilo Pump -- Circulation
Wilo Pump -- Helix Excel
Wilo Pump -- IL/IPL Inline
Wilo Pump -- MTS Submersible Grinder
Wilo Pump -- MVI Vertical Multistage
Wilo Pump -- NL End Suction Base Mount
Wilo Pump -- Sump/Effluent Pumps
Wilo TWI Submersible Well Pump
Wilo TWU Submersible Well Pump
Testers / Measurement
Flow Meters
Clean Energy / Energy Saving
Solar Panels
Solar Inverters
Enphase
Fronius
Magnum
MidNite Solar
OutBack Power
Schneider Electric
SMA Solar
SolarEdge
SolaDeck
Renewable Energy Batteries
Lithium Ion Batteries
ForeverPure Power Batteries
Forklift Batteries
Battery Cables
Solar Racking
Ground Mount
Unirac
Solar Carport
Solar Powered Water Systems
Variable Frequency Drives (VFD)
Schneider ATV61
Schneider ATV212
Containerized Energy Systems
Home
>
Membranes - RO/UF/NF
>
Hydranautics
>
Hydranautics HYDRAcap 80 Capillary Ultrafiltration Module
Please contact ForeverPure for Pricing. (Call 408-969-2688 ext. 1 for Sales Department)
Product Code:
HYDRACAP-80
Qty:
Description
Spec Sheet / Manual
Technical Specifications
Hydranautics HYDRAcap 80 Capillary Ultrafiltration Module, 80"
HYDRAcap is used to treat surface water, ground water, seawater and waste water as either primary treatment or as pretreament to reverse osmosis (RO) and nanofiltration (NF). Compared to conventional pretreatment, HYDRAcap allows higher fluxes for RO and NF systems while maintaining longer intervals between cleanings. In some cases it replaces conventional pretreatment for potable applications, ground water recharging and water recycling.
HYDRAcap and HYDRAcap LD
The 0.8 mm HYDRAcap is used for surface water applications containing lower turbidities. The 1.2 mm HYDRAcapLD offers a 50% larger capillary diameter for a wider range of high fouling applications.
Providing Reliable and Cost-Effective Integrated Membrane Solutions (IMS®)
HYDRAcap enhances RO and NF element system design and operating conditions when used as a pretreatment step for desalination, treatment of surface waters and municipal and industrial effluents.
Performance
Filtrate Flow:
16.3 – 39.5 gpm (3.7 – 9.0 m3/h)
Filtrate Turbidity: ≤ 0.07 NTU
Virus removal: ≥4 log
Bacteria removal: ≥4 log
Application Data
Typical Filtrate Flux Range
35 – 85 gfd (59 – 145 l/m2/h)
Maximum Applied Feed Pressure
73 psig (5.0 bar)*
Operating Mode
Inside to Outside Filtration Direct flow or Crossflow
Maximum Transmembrane Pressure
20psig (1.4bar)
Maximum Backwash Transmembrane Pressure
20psig (1.4bar)
Instantaneous Chlorine Tolerance
100 ppm
Instantaneous Hydrogen Peroxide Tolerance:
200 ppm**
Maximum Chlorine Exposure
200,000 ppm-hrs
Maximum Instantaneous Feed Turbidity
100 NTU
Maximum Operating Temperature
104 F (40 C)
pH Operating Range
4.0 -10.0
Cleaning pH Range
1.5 –13.0
*At 68°F (20°C)
** For 60 minutes or less.
***Higher values can be treated. Consult Hydranautics’ technical staff.
†Typical module performance for most feedwaters.
‡The limitations shown here are for general use. The values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.
HYDRAcap 80 Datasheet
Performance
Filtrate Flow:
16.3 – 39.5 gpm (3.7 – 9.0 m3/h)
Filtrate Turbidity: ≤ 0.07 NTU
Virus removal: ≥4 log
Bacteria removal: ≥4 log
Application Data
Typical Filtrate Flux Range
35 – 85 gfd (59 – 145 l/m2/h)
Maximum Applied Feed Pressure
73 psig (5.0 bar)*
Operating Mode
Inside to Outside Filtration Direct flow or Crossflow
Maximum Transmembrane Pressure
20psig (1.4bar)
Maximum Backwash Transmembrane Pressure
20psig (1.4bar)
Instantaneous Chlorine Tolerance
100 ppm
Instantaneous Hydrogen Peroxide Tolerance:
200 ppm**
Maximum Chlorine Exposure
200,000 ppm-hrs
Maximum Instantaneous Feed Turbidity
100 NTU
Maximum Operating Temperature
104 F (40 C)
pH Operating Range
4.0 -10.0
Cleaning pH Range
1.5 –13.0
*At 68°F (20°C)
** For 60 minutes or less.
***Higher values can be treated. Consult Hydranautics’ technical staff.
†Typical module performance for most feedwaters.
‡The limitations shown here are for general use. The values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.